Polarization Maintaining Filter Coupler
1x2, 2x2 (830nm)
Polarization Maintaining Filter Coupler is a polarization maintaining coupler which either splits the light from the input PM fiber into two output PM fibers, or combines light signals from two PM fibers into a single PM fiber. The state of polarization can be aligned either with the slow axis or the fast axis of the PM fibers. The device can be used to split high power linearly polarized light into multiple paths without perturbing the line are state of polarization (SOP).It can also be used as a power tap to monitor signal power in a PM fiber system without disturbing the linear SOP of light propagating in the PM fiber. Applications include PM fiber interferometers, power sharing in polarization sensitive systems, and signal monitoring in PM fiber systems. The rugged stainless steel package is designed for high optical performance and stability. This compact device offers low excess insertion loss, low back reflection, and high extinction ratio. Split ratios from 1 to 50% are available.
Specification
Parameter |
Unit |
Value |
Center Wavelength |
nm |
830 |
Operating Wavelength Range |
nm |
+/-15 |
Configuration |
|
1x2 |
2x2 |
Max. Excess Loss |
dB |
1.2 |
1.4 |
Max Uniformity(only for 50/50) |
dB |
0.6 |
0.8 |
Tap Ratio |
% |
1±0.2%,2±0.4%,5±1.0%, 10%, 20%, 30%, 40% and 50% or Specify |
Min. Return Loss |
dB |
50 |
Min. Extinction Ratio
(only for F Type) |
dB |
20 |
Max.Optical Power |
mW |
300 |
Max. Tensile Load |
N |
5 |
Operating Temperature |
℃ |
-5 to +70 |
Storage Temperature |
℃ |
-40 to +85 |
Fiber Type |
HI 780 or PM 850 Panda Fiber on Tap Port |
PM 850 Panda Fiber on lnput&Output Port |
Above specification is for device without connectors.
PM fiber and connector key are aligned to the slow axis. And for F type, fast axis is blocked.
Device with connectors, IL will be 0.3dB higher, RL will be 5dB lower and ER will be 2dB lower.